Tool configuration, documented as it happens
Captur watches an equipment configurator, captures every change on screen and every button pressed, and turns the session into a PDF report you review before it is issued.
Configuring a downhole tool leaves little room for paperwork. The engineer is working with the equipment, and the record of what was done gets written up afterwards, from memory, if at all.
Taking screenshots by hand fails in a specific way: the engineer is busy with the equipment, so screenshots get skipped, and the write-up happens hours later when the detail is gone. The configurator's own log records values, but not the steps and not what the screen actually showed.
Captur removes the choice. Capturing is automatic; the only part that needs attention — the commentary — happens afterwards. The result is a report that shows what was done to the tool before it went into the well: which settings were written, in what order, and when.
Most configurators for this kind of equipment are built with LabWindows/CVI, and a CVI panel is a single window with every button painted onto it. There are no child windows, so the usual ways of asking Windows what the user just clicked return nothing at all — the caption exists only as pixels.
Captur does not try to read it. It marks the spot: every click is drawn on the screenshot as a numbered ring at the exact point the operator pressed, and the same number appears in the list of actions beside the page. Where Windows can name the control, the name is recorded as well; where it cannot, the mark is the whole record — and a mark is never a guess, which a read caption always is.
Putting that mark in the right place is the hard part. A LabWindows/CVI panel is DPI-unaware: on a scaled display Windows stretches the picture the application drew, so a screenshot comes back smaller than the space the window occupies on screen, and every position measured on it is wrong by the same factor. Captur asks the window and its monitor what resolution each is working at and corrects the difference. Checked against real windows at both 100% and 125% scaling; on the printed page the mark lands within about 1.3 points of the click.
For a panel that will not sit still — a live chart, a settling reading — waiting for the screen to change would save a frame every few seconds and none of them would mark anything the operator did. Captur can be switched to capture on the operator's actions instead: a frame just after each click, and nothing in between.
| Platform | Windows, 64-bit. Developed and tested on Windows 11. |
|---|---|
| Install | None. Single executable, or a portable folder. |
| File size | 19.7 MB single file · 68.1 MB unpacked |
| Start | about 6 s the first time (unpacks itself once), about 1 s afterwards |
| Network | None. No sockets, no telemetry, no licence check. |
| Output | PDF, plus the raw PNG frames and a JSON session file |
| Requires | Nothing to install. No language pack, no OCR engine, no runtime. |
| Built with | Python compiled to native code with Nuitka (not a packed interpreter) · PySide6 (Qt) · reportlab · mss and the Win32 API · Windows UI Automation called directly through ctypes |